Martek home - power supplies



NL Series (NL100)
100 Watt Single/Dual Output(s) Power Supply

NL100

download NL100 data sheet with case drawing

 

Features
0.38 Inch Profile
Remote Turn On (TTL)
Output Voltage Trim Pin
Over Temperature Protection
MIL-STD-883 Screening (Military Version)
Output Overvoltage/Overcurrent Protection

 

nlorder.jpg (20266 bytes)

How To Order
Series: NL
Total Output Power: 100
Output: "S" for Single, "D" for Dual
Product Grade: "M" for Military              
"I"  for Industrial
Output Voltage: 2/3.3/5/5.2/12/15
Options: A/B/C/D/I
 

 

 

Options
A Option: Pins out side of unit.
B Option: Pins out bottom of unit.
C Option: Pins out top of unit.
D Option: Through hole inserts (STD threaded) .0115 DIA thu holes.
I Option: M2.5 inserts.
 

 

 

Accessory Products
NLF150: EMI Filter to meet MIL-STD-461D Compliance CE101 & CE102.


Selection Chart
Nominal Output (Vdc) Single Output Current (Amps) Dual Per Channel Current (Amps)
2.0 20 10
3.3 20 10
5.0 20 10
5.2 19.2 9.6
12 8.3 4.2
15 6.7 3.3

 

 

Input Characteristics

Min Typ Max Units
Input Voltage 9 12 18 Vdc
Brown Out (75%) Full Load 7
Vdc
No Load Power Dissipation
1 2 Watt
Inrush Charge
3.5 mc
Reflected Ripple Current
3
%
Logic Disable Current (Sink)
100 150 µA
Logic Disable Power In
0.5 1 W
Input Ripple Rejection
(120 Hz)

50
dB
Input Ripple Rejection
(800 Hz)
40 dB
Efficiency (FL) 72 78-85   %
Efficiency (3.3Vdc) (FL) 70 75 %
Efficiency (2Vdc) (FL) 63 69 %
EMI Units conform to MIL-STD-461D (on the input leads) with companion filter
Input Transient Units can withstand 24V transients for up to 0.1 second

 

 

Output Characteristics

Min Typ Max Units
Set Point Accuracy     1* % Vout
Load Regulation
10 30 mV
Line Regulation
5 25 mV
Ripple P-P (10 MHz)
50 150 mV
Trim Range 100
110 % Vout
Remote Sense Compensation 0.5 Vdc
Overvoltage Protection(2V, 3.3V) 140 % Vout
Overvoltage Protection(5V- 15V) 130 % Vout
Current Sharing +/- 10 % Iout
Transient Response (% Vout 1%) Time / Overshoot
    20 - 80% Load
300 / 250
µS/mV
    Low Line - High Line
250 / 200   µS/mV
    50 - 100% Load
250 / 200
µS/mV
Temperature Drift   0.01 0.05 %/oC
Long Term Drift   0.01 0.02 %/1KHrs
Current Limit 105 125 150 % Iout
Short Circuit Current 20 75 % Iout
Turn On Time
3   mS
Logic Turn On Time   3 mS
* 1% or 50mV, whichever is greater

 

Isolation Characteristics

Min Typ Max Units
Isolation:
  Input to Output
250

Vdc
  Output to Base 100

Vdc
  Input  to Base 100 Vdc
Input to Output
  Capacitance

0.044
µF
Insulation Resistance
  (@50 Vdc)
50

MOhm

 

 

Mechanical Characteristics
Weight 6.4 oz
  180 grams
Size 3.0 x 3.0 x 0.38 inch
  76.2 x 76.2 x 9.7 mm
Volume 3.42 inch3
  56.0 cm3


Temperature Characteristics

Min Typ Max Units
Operating -55 +100 oC
Storage (Ambient) -55
+125 oC
Over Temperature Shutdown +105 oC
Thermal Resistance Case - Ambient
9
oC/W


Environmental Screening - M Model
Stabilization Bake: +125oC for 24 hours similar to Mil-Std-883, M1108, Condition B
Temperature Cycling: 10 cycles at -55oC to +125oC (transition period 36 minutes) similar to Mil-Std-883, M1010, Condition B
Burn-in: 160 hours at +85oC minimum
Final Testing

 

Environmental Screening - I Model
Burn-in: 16 hours at +85oC minimum
Final Testing